
Quantify fluorescence microscopy images without writing a macro. Upload an RGB merge or a multi-channel TIFF and choose the nuclear and marker channels. You get mean intensity, integrated density and % positive area for your marker, an automatic count of nuclei with the marker intensity of each one, the percentage of positive cells against a threshold you set, and Pearson and Manders colocalisation between two markers.
Privacy: everything runs inside your web browser. Your images and data are not uploaded to any server, which makes the tool safe for unpublished results.
How to use it
- Upload a raw image from the microscope: an RGB merge, or a TIFF with one channel per page (8- or 16-bit).
- Choose the nuclear channel (DAPI or Hoechst) and marker A. Choose marker B as well for colocalisation.
- Optionally draw a region. Enter a positive-cell threshold taken from a negative control if you want % positive cells.
- Press Analyse, check the detected nuclei overlay, then download the summary and the per-nucleus table.
What it measures
- Mean intensity and integrated density of marker A after background subtraction.
- % positive area using an automatic Otsu threshold, which suits structural markers such as cytoskeleton or extracellular matrix.
- Nuclei count from the nuclear channel, with size limits to remove debris and flag merged nuclei.
- Per-nucleus marker intensity and the distribution chart. % positive cells uses your threshold.
- Colocalisation: Pearson’s r for overall correlation, and Manders M1 and M2 for the fraction of each marker overlapping the other.
Good practice
- Acquire every image you compare with identical exposure, gain and laser power, and avoid saturated pixels (the tool reports them).
- Set the positive-cell threshold from a secondary-only or isotype control, not by eye on the treated sample.
- For colocalisation use separate raw channels, check for bleed-through between channels, and report Manders together with Pearson.
- Analyse several fields per sample and treat biological replicates as your n.
Suggested methods text
“Fluorescence images were quantified with the DailyFirst Immunofluorescence Quantification tool (dailyfirst.in): background was subtracted per channel, nuclei were segmented from the DAPI channel by Otsu thresholding, and mean marker intensity was measured per nucleus. Colocalisation was assessed by Pearson’s coefficient and Manders’ M1/M2.”
Frequently asked questions
Why is % positive cells not calculated automatically?
An automatic cutoff can call cells positive even when there is no real staining. A threshold from a proper negative control is the defensible approach.
Touching nuclei are counted as one.
Very crowded nuclei can merge. They are flagged by the maximum size setting. Choose less crowded fields, or analyse at a higher magnification.
Can I measure cytoplasmic staining per cell?
Per-cell values are measured inside each nucleus. For cytoplasmic markers use the mean intensity and % area results, which cover the whole image or region.
More tools in the DailyFirst Research Lab
- Western Blot Densitometry
- IHC Quantification (DAB)
- RT-qPCR ΔΔCt & Pfaffl Calculator
- ELISA Standard Curve Calculator
- Molarity & Dilution Calculator, mg/mL to Molarity Converter, Percent Solution Calculator, Serial Dilution & CFU Calculator
- See every tool in the Research Lab · t-test and statistics tools for your results



