Serial dilutions come up all the time in microbiology, cell culture, ELISA standards and qPCR standard curves. This calculator does three jobs. It plans a dilution series tube by tube, turns a colony count into CFU/mL for your original sample, and works backwards from a rough guess of your sample’s concentration to tell you which dilutions to plate for a countable result (30–300 colonies by default).
Formulas used
- Transfer volume = final volume per tube ÷ dilution factor
- Diluent volume = final volume − transfer volume
- Concentration in tube n = starting concentration ÷ (dilution factor)ⁿ
- CFU/mL = colonies ÷ (dilution of plated tube × volume plated in mL)
- Expected colonies = CFU/mL × dilution × volume plated (mL)
Worked examples
- Ten-fold series, 1 mL tubes: transfer 0.1 mL into 0.9 mL diluent at each step. Starting at 10⁸ cells/mL, tube 6 holds 10² cells/mL.
- Two-fold series for a standard curve, 200 µL tubes: transfer 100 µL into 100 µL each time. Starting at 100 µg/mL gives 50, 25, 12.5, 6.25 and 3.125 µg/mL.
- Plate count: 150 colonies from 100 µL of the 10⁻⁶ tube = 150 ÷ (10⁻⁶ × 0.1) = 1.5 × 10⁹ CFU/mL.
- Planning: if an overnight culture is somewhere between 10⁷ and 5 × 10⁸ CFU/mL and you plate 100 µL, plate the 10⁻⁴, 10⁻⁵ and 10⁻⁶ tubes to be sure of a countable plate.
Tips from the bench
- Mix every tube well (vortex or pipette up and down) before taking the next transfer. Poor mixing is the most common reason for odd counts.
- Change tips between tubes. Carry-over from a concentrated tube inflates every later tube.
- Count plates in the 30–300 range. Above 300 colonies merge (TNTC, too numerous to count). Below 30 the random error is large (TFTC, too few to count). Some labs use 25–250. You can change the range in the planner.
- Plate in duplicate or triplicate and average the counts for a more reliable CFU/mL.
- Report with the dilution. Write the counts, the plated tube and the volume in your notebook so the calculation can be checked later.
Frequently asked questions
What is a dilution factor?
How many times weaker each tube is than the one before. A ten-fold (1:10) dilution has a dilution factor of 10. After three ten-fold steps the total dilution is 10³ (written 10⁻³).
How do I calculate CFU/mL?
Divide the colony count by the dilution of the tube you plated and by the volume you spread in mL. 85 colonies from 0.1 mL of the 10⁻⁵ tube = 85 ÷ (10⁻⁵ × 0.1) = 8.5 × 10⁷ CFU/mL.
Can I use this for cell counting or ELISA standards?
Yes. The dilution series works with any unit: cells/mL, µg/mL, ng/mL, copies/µL or mM.
More free lab calculators
- Molarity & Dilution Calculator (grams to weigh, molarity from mass, C1V1 = C2V2)
- Mass Concentration ↔ Molarity Converter
- Percent Solution Calculator
- All analytical and statistics tools (t-test, ANOVA, correlation, regression, graphs)